SkinTemp: biosynthetic skin dressing
SkinTemp is a unique composite nylon mesh to which a prorous collagen membrane is attached. As such, it is a new innovation in the biomaterials industry. Collagen can remain in contact with a wound and the nylon peeled off without disturbing the wound.  

Application of pressure to the nylon edges increases pore size in the nylon allowing exudate to flow to the surface where it can be easily wiped off. This material has limited permeability and is biocompatible. SkinTemp can be used as a temporary burn dressing prior to grafting or on donor graft sites.

 
   Properties    Properties of an "ideal" dressing 
  • Sterile
  • Protective bacterial barrier
  • Does not impede  healing
  • Biodegradeable
  • Reduction of water, electrolytes and heat loss
  • Fluid control for light, moderate or heavily exudating wounds
  • Readily available
  • Conforms
  • Strong
  • Easy to apply and remove
  • Cost effective
  • Rapid and sustained adherence 
  • Sterile, hypoallergenic, non-toxic, non-pyrogenic 
  • Fluid control similar to skin 
  • Flexible, pliabile, elastic 
  • Durable 
  • Impermeable to exogenous microorganisms 
  • Easy to apply and remove 
  • Easy to store, readily available and cost effective 
  • Hemostatic 
  • Structure promotes growth of fibro-vascular tissue 
  • Biodegradable 
 
   Application     Common uses of Skin Temp
  • Clean application site in usual manner. 
  • Treat with medication if desired. 
  • Apply collagen side onto the surface of the wound. Collagen may be soaked in saline before application on sensitive or dry wounds. 
  • For removal, simply lift off. If necessary, wet with saline solution prior to removal. 
  • Replace as required.
  • Burns 
  • Donor sites 
  • Graft sites 
  • Scrapes and cuts 
  • Cutaneous ulcers 
  • Draining wounds 
  • Dermatologic conditions 
  • Partial thickness wounds 
 
Availability  
 
SIZE
QUANTITY
REORDER NUMBER
2" x 3"
10/box
ST 1001
3" x 4"
10/box
ST 1002
8" x 14"
10/box
ST 1003
 
  Precautions
SkinTemp should not be used on infected or contaminated spaces. All open and unused portions must be discarded. Not to be used on persons sensitive to materials of bovine origin. 

Some adverse reactions such as transitory pain, bleeding, blistering, edema and erythema have occasionally been reported in isolated cases.

 
Envy International
5, Sharda 'A' Road, Churchgate, Mumbai-400 020.
Phone : 3092347, 309 7923, 204 6887 • Fax : 91-22-308 0197